Test index: Optical density(OD) and specific optical density(DS) of the smoke
Measuring principle: Lambert-beer Law
Measuring method: Measure the smoke light transmission percent of original light transmission to represent smoke density, and calculate the max DS by min percentage of the transmission
Standard: IEC 61034
Technical parameters:
Burning device:
- Use the long pole ignition devices to ensure the testing personnel’s safety
Stainless steel flame testing machine stand allocated with a automatic sample fixture
Stainless steel alcohol tray: Internal size of the bottom: 210mm×110mm
Internal size of the head: 240mm×140mm
Height: 80mm
Optical system:
- Use the restructured optical system light source which is imported by Germany
The light receptor is made of imported high resolution batteries
Tungsten quartz-halogen lamp: Voltage: DC 12V, Power: 100W, Nominal luminous flux: 2000lm~3000lm, Nominal color temperature: 2800K~3200K, Lens light beam: 1.5m±0.1m adjustable
- Testing software: Smoke density DAQ testing software, the light path calibration system: 0, 100% spot calibration, which is available to operated on laptop and desktop computerboth
Specifications:
- Control cabinet dimensions: 600mm(W)×600mm(D)×1600mm(H)
- Power supply: AC 220V, 50/60Hz, 1A
- Burning box dimensions: 3m×m×3m(optional for users)
- Computer: (optional for users)
Reviews