Multifunctional Electrical Safety Tester Features:
– High-precision: accuracy of 1%, industry first;
– High speed: patented technology (grounding, voltage withstand parallel test), fast, efficient
– Comprehensive: integrated safety performance and electrical performance test, one station, one-key start;
– Intelligent: Built-in 100 groups of test conditions in memory;
– Automation expansion: RS232/Rs485/GPIB/Ethernet interface (four choose one), bar code scanning interface, variable frequency power control interface to composing an automated Analyser.
Multifunctional Electrical Safety Tester
Multifunctional Electrical Safety Tester Regulatory compliance
Type | Standard Number | Description |
Household products | IEC 60950/GB4943 | IT Equipment |
IEC 60065/GB8898 | Audio visual equipment | |
IEC 60335/GB4706 | Household appliances | |
Equipment/instruments | UL 61010-1/GB4793 | Laboratory test equipment |
UL 60601-1/GB9706 | Medical equipment | |
Power | UL1310 | Class 2 Power |
UL 1778/GB T7260 | UPS equipment | |
Transformers | UL 1411 | Transformers and motor transformers for audio-visual or television equipment |
UL 1585 | Class 2 and 3 transformers (for products with exposed wiring, ensure that there is no risk of electric shock, etc.) | |
IEC 61558-1/GB19212 | Power transformers, power supply and other safety requirements |
Function expansion & type
Model | Function |
AN1640B | Desktop seven-in-one safety comprehensive analyser, 200VA output capacity |
AN1640BP | Desktop seven-in-one safety comprehensive analyser, 500VA output capacity |
AN1651B | Cabinet seven-in-one safety comprehensive analyser, 200VA output capacity, built-in 6kW inverter power supply |
AN1651BP | Cabinet seven-in-one safety comprehensive analyser, 500VA output capacity, built-in 6kW inverter power supply |
Multifunctional Electrical Safety Tester Specifications
AC withstand voltage test | ||||
Rated output capacity | 200VA (5000V/40mA), short circuit current is greater than 200mA; (Optional: 500VA (5000V/100mA), short-circuit current greater than 200mA;) |
|||
Output voltage | Range/accuracy | 100~5000V, ±(1%× setting +5V) | ||
Output frequency | Range/accuracy | 50Hz or 60Hz, ±0.1%× setting | ||
Alarm current | Upper limit/accuracy | 0.10~40.00mA, ±(1%× setting +5 words) | ||
Lower limit /accuracy | 0.000~9.999mA, ±(1%× setting +5 words) | |||
Time | Range | 0.5~999.9s (0: infinite time) | ||
Ramp-up time | 0.1~999.9s (0: off) | |||
Ramp-down time | 0.1~999.9s (0: off) | |||
Accuracy | ± (0.2%× setting +1 word) | |||
Measure meter | Voltage range/accuracy | 0.01~5.00kV, ± (1%× reading +2 words) | ||
Current range/accuracy | 0.10~40.00mA, ± (1%× reading +5 words) | |||
Time range/accuracy | 0.1~999.9s, ± (0.2%× reading +1 word) | |||
Output voltage wave, distortion, adjusting rate | Sine wave, less than 2% (pure resistive load), ± (1% × setting + 5V) (from zero to full load) | |||
Start voltage | (0%~50%)× output voltage setting | |||
Current compensation | 0.000~40.00mA, Auto/manual | |||
Arc detection | Level 1~9, 9: highest level; 0: off | |||
DC withstand voltage test |
||||
Output voltage | Range/accuracy | 100~6000Vdc, ± (1%× setting +5V) | ||
Alarm current | Upper limit/accuracy | 0~10000μA, ± (1%× setting +5 words) | ||
Lower limit /accuracy | 0.0~999.9μA, ± (1%× setting +5 words) | |||
Time | Range | 0.5~999.9s(0: infinite time) | ||
Ramp-up time | 0, 0.4~999.9s (0: off) | |||
Ramp-down time | 0, 1.0~999.9s (0: off) | |||
Accuracy | ± (0.2%× setting +1 word) | |||
Measure meter | Voltage range/accuracy | 0.01~6.00Vdc,±(1%× reading +2 words) 0.01~6.00Vdc, ± (1%× reading +2 words) |
||
Current range/accuracy | 0.0~10000uA, ± (1%× reading +5 words) | |||
Time range/accuracy | 0.1~999.9s, ± (0.2%× reading +1 word) | |||
Rated output capacity | 60VA(6000Vdc/10mA) | |||
Output adjustment | ± (1%× setting +2V), zero to full load | |||
Compensation current | 0 ~200.0μA, Auto/manual | |||
Start voltage | (0%~50%)×output voltage setting | |||
Charging current lower limit | (0~3.500) μA, Auto/manual | |||
Discharge time | ≤200ms | |||
Arc detection | Level 1~9, 9: highest level; 0: off | |||
Insulation resistance test |
||||
Output voltage | Range/accuracy | 100~2500Vdc, ± (1%× setting +5V) | ||
Alarm resistance | Upper/lower limit | 0.1MΩ~999.99MΩ,1000MΩ~50000MΩ 0.1MΩ~999.99MΩ, 1000MΩ~50000MΩ, the upper limit includes no upper limit setting |
||
Accuracy | 100-499V, 0.10MΩ~999.99MΩ, 1000~2000MΩ, ± (5%× setting +2 words) 500-2500V, 0.10~999.99MΩ, ± (2%× setting +2 words), 1000~9999MΩ, ± (5%× setting +2 words) 10000~50000MΩ, ± (15%× setting +2 words) |
|||
Time | Ramp-up time | 0,0.1~999.9s (0: off) | ||
Delay decision time | 0, 0.5~999.9s (0: infinite) | |||
Range | 0, 0.5~999.9s (0: infinite) | |||
Ramp-down time | 0, 1.0~999.9s (0: off) | |||
Accuracy | ± (0.1%× setting +0.1s) | |||
Measure meter | Voltage range/accuracy | 100~2500Vdc, ± (2%× reading +5 words) | ||
Resistance range/accuracy | Range: 0.100 MΩ~9.999 MΩ, 10.00 MΩ~99.99 MΩ, 100.0 MΩ~999.9 MΩ, 1.000 GΩ~50.00GΩ Resolution: 0.001 MΩ, 0.01 MΩ, 0.1 MΩ, 0.001GΩ, 0.01GΩ 100-499V, 0.10~9.999MΩ, 10.00~99.99MΩ, 100.0~999.9MΩ, 1~2GΩ, ± (5%× reading +2 words) 500-2500V, 0.100~9.999MΩ, 10.00~99.99MΩ, 100.0~999.9MΩ, ± (2%× reading +2 words), 1.000~9.999GΩ, ± (5%× reading +2 words) 10.00~50.00GΩ, ± (15%× reading +2 words) |
|||
Time range/ accuracy | 0.1~999.9s, ± (0.2%× reading +1 word) | |||
Charging current lower limit | 0~3.500μA, Auto/manual | |||
Grounding resistance test |
||||
Rated output | Maximum output current: 32A; maximum test resistance: 600mΩ; maximum open circuit voltage: 12V | |||
Output current | Range/accuracy | 2.0~32.0A, ± (1%× setting +2 words) | ||
Output voltage | Range/accuracy | 3.0~6.4V , ± (1%× setting +2 words) | ||
Output frequency | Range/accuracy | Sine wave, 50Hz or 60Hz, ±0.1%× setting | ||
Alarm limit | Resistance upper/lower limit | Range: (0.1~600)mΩ (2.0~10.6)A; (0.1~R)mΩ (10.7~32.0)A, R= (6400/current setting) mΩ. As the current scale is switched, the tester will automatically calculate the maximum scale. Resolution: 0.1/1 mΩ |
||
Error | ± (1%× setting +2 words) | |||
Compensation resistance | Range | 0~100 mΩ, automatic measurement , compensation On/Off | ||
Test time | Range/accuracy | 0.5~999.9s (0: infinite); ± (0.2%× setting + 1 word) | ||
Measure meter | Current range/accuracy | 2.0~32.0A( or 64A), ± (1%× reading +2 words) | ||
Voltage range/accuracy | 3.0~10.0V , ± (1%× reading +2 words) | |||
Resistance range/accuracy | 10.0~99.9~100~600mΩ;± (1%× reading +2 words) | |||
Time range/accuracy | 0.5~999.9s (0: infinite); ± (0.2%× setting +1 word) | |||
Leakage current test |
||||
Leak test body network (MD card) | Standard network, GB/T 12113 Fig. 4; (Optional: other leak test network) | |||
Probe position | Ground leakage current: G-L, G-N, AUTO (G-L, G-N); Surface leakage current: PH, PL | |||
Test power state | Polarity switch: On/Off/Auto; Ground switch: On/Off Zero line connection switch: On/Off |
|||
Test voltage output | Single-phase, with external isolation transformer or variable frequency power supply to provide the required test voltage and frequency. | |||
Test voltage upper/lower limit | Upper/lower limit Range: 0.0V~300.0V AC, Resolution: 0.1V, 45Hz~65Hz, Error: ± (0.4%× setting +0.1%× scale) |
|||
Test voltage measurement | Range: 0.0V~300.0V, 45Hz~65Hz, Resolution: 0.1V, 45Hz~65Hz, Accuracy: 20.0V~300.0V: ± (0.4%× reading +0.1%× scale) |
|||
Load current | 20A | |||
Current upper/lower limit (RMS) | Range: 0.0uA~999.9uA, 1000uA~9999uA, 10.00mA~12.00mA Resolution: 0.1uA, 1uA, 0.01mA Error: 0.0uA~999.9uA: DC: ± (1.5%× setting + 10 words) 15Hz≤f≤100kHz: ± (1.5%× setting + 10 words) 100kHz<f≤1000kHz, 10.0uA~999.9uA: ±5%× setting 1000uA~7999uA: DC: ± (1.5%× setting + 10 words) 15Hz≤f≤100kHz: ± (1.5%× setting + 10 words) 100kHz<f≤1000kHz, 10uA~7999uA: ±5%× setting 8.00mA~12.00mA: DC: ± (1.5%× setting + 10 words) 15Hz≤f<1000kHz, 0.01mA~12.00mA: ±5%× setting |
|||
Current measurement (RMS) | 0.0uA~999.9uA: Resolution: 0.1uA DC: ± (1.5%× reading + 10 words) 15Hz≤f≤100kHz: ± (1.5%× reading + 10 words) 100kHz<f≤1000kHz, 10.0uA~999.9uA: ±5%× reading 1000uA~7999uA: Resolution: 1uA DC: ± (1.5%× reading + 10 words) 15Hz≤f≤100kHz: ± (1.5%× reading + 10 words) 100kHz<f≤1000kHz, 10uA~7999uA: ±5%× reading 8.00mA~12.00mA: Resolution: 0.01mA DC: ± (1.5%× reading + 10 words) 15Hz≤f<1000kHz, 0.01mA~12.00mA: ±5%× reading |
|||
Current compensation | Range: 0.000 ~ 1.000mA, automatic measurement, On/Off. | |||
Test time | Range: 0, (1 ~ 999.9), 0: infinite, Resolution: 0.1s, accuracy: ± (1% × setting +1 word). When the test mode is AUTO (G-L, G-N), the time is half. | |||
Power parameter test |
||||
Power parameter test | Alarm | Power upper/lower limit alarm; On/Off of upper/lower limit alarm of voltage, current and power factor. |
||
Power upper/lower limit | Range: 0.00W~99.99W, 100.0W~999.9W, 1000W~6000W Resolution: 0.01W, 0.1W, 1W Accuracy:±(0.1%× setting +0.1%× scale) |
|||
Active power measurement | Range: 0.100W~9.999W, 10.00W~99.99W, 100.0W~999.9W, 1.000kW~6.000kW, Resolution: 0.001W, 0.01W, 0.1W, 0.001kW Accuracy: PF>0.5: ± (0.1%× reading +0.1%× scale) PF≤0.5: ± (0.4%× reading +0.1%× scale) |
|||
Voltage upper/lower limit | When voltage alarm is On Range: 0.00V~99.99V, 100.0V~300.0V, Resolution: 0.01V, 0.1V; Error: ± (0.1%× setting +0.1%× scale), 45Hz≤f≤65Hz |
|||
Voltage measurement | Scale: 300V, crest factor ≤1.6 Range: 5.00V~99.99V, 100.0V~300.0V, Resolution: 0.01V, 0.1V; Resolution:± (0.1%× reading +0.1%×scale), 45Hz≤f≤65Hz |
|||
Current upper/lower limit | When current Alarm is On Range: 0.00mA~99.99mA, 100.0mA~999.9mA, 1.000A~9.999A, 10.00A~20.00A Resolution: 0.01mA, 0.1mA, 0.001A, 0.01A Error: ± (0.1%× setting +0.1%× scale), 45Hz≤f≤65Hz |
|||
Current measurement | Range: 20A, crest factor ≤1.6 Range: 10.00mA~99.99mA, 100.0mA~999.9mA, 1.000A~9.999A, 10.00A~20.00A Resolution: 0.01mA, 0.1mA, 0.001A, 0.01A Resolution: ± (0.1%× reading +0.1%× scale), DC, 45Hz≤f≤65Hz, |
|||
Power factor upper/lower limit | When power factor alarm is On Range: ± (0.100~1.000), Resolution: 0.001 |
|||
Power factor measurement | Range: ± (0.100~1.000), Resolution: 0.001 Resolution: ±0.01(Voltage/current amplitude is greater than 10% of the corresponding scale) |
|||
Frequency | Range: 45.00Hz≤f≤65.00Hz, Resolution: 0.01Hz | |||
Test time | Range: 0, (0.5~999.9)s, 0: infinite, Resolution: 0.1s, Resolution: ± 0.2% × setting +1 word |
|||
LV Start Test |
||||
LV Start Test | Current upper/lower limit | Range: (0.00~25.00)A, Resolution: 0.01A Error: ± (0.1%× setting +0.1%× scale) |
||
Current measurement | Range: 25A, crest factor ≤1.6 Range: (0.02~25.00)A, Resolution: 0.01A Resolution: ± (0.1%× reading +0.1%× scale), 45Hz≤f≤65Hz |
|||
Voltage measurement | Range: 300.0V, crest factor ≤1.6 Range: 5.00V~300.0V, Resolution: 0.01V/0.1V; Resolution: ± (0.1%× reading +0.1%× scale), 45Hz≤f≤65Hz |
|||
Test time | Range: 0, (0.5~999.9)s, 0: infinite, Resolution: 0.1s, Resolution: ± 0.2% × setting +1 word |
|||
General Specification | ||||
Verification & Calibration environment | 23℃±5℃, (45~75) %RH , less dust | |||
Operating environment | 0 ~40℃, , (5~90) %RH , less dust | |||
Storage environment | -10~55℃, (5~95) %RH , less dust | |||
Power supply | 220V±10%,50Hz±5% | |||
Power consumption | Maximum 1000VA (excluding operating power of objects under test) | |||
AN1640B | Weight (excluding packaging) | Approx. 40kg | ||
Dimension (excluding packaging, mm) | 483(W)x 550(D)x 175(H) | |||
AN1651B | Weight (excluding packaging) | Approx. 80kg | ||
Dimension (excluding packaging, mm) | 483(W)x 600(D)x 1355(H) |