Main features
* Latest international standard: Comply with CCC, IEC/ EN, VDE, BS, UL, JIS standards requirements.
* Standard A MD card
* Measurement bandwidth DC-1MHZ
* Leakage current upper/lower limit setting, intelligent judgment, sound and light alarm.
* VFD display, simple operation
* Remote, RS232/485 interface
Technical Parameters:
Model | AN 9620X (F) single phase | AN 9620TX (F) three phase |
Input power supply | 220V AC±10%, 50Hz | |
Test input current | 12A AC MAX | |
Built in MD range/Accuracy | Standard A MD card | |
Inner MD | Standard configuration figure 4 in GB12113,compliant with MD demand in new standard GB4706.1-2005 Other type MD can be ordered. | |
Leakage current measurement range and resolution | 0.010~0.999mA~10.00Ma | |
Leakage current accuracy | 10μA~50μA | DC~1MHz: ±(5% of reading+5μA ) |
50μA~10.00mA | DC~10KHz: ±(3% of reading+2μA )
10KHz~1MHz: ±(5% of reading+5μA ) |
|
Leakage current alarm preset | 0.050~10.00mA | |
Measurement time setting range | 1~999s ( LLL= continues output|); Accuracy: ±1% | |
Interface function | RS232 ( RS485 optional),Remote control | |
Dimension (W×H×D) | 320×110× 400mm |
More
Model | AN 9620TH (F) | AN 9620D (F) | AN 9640B (F) |
Description | Multiple network Leakage Current analyser
Accuracy: 2%; 7 kings of built-in networking MD card for leakage current test |
DC Leakage Current Tester
Accuracy: 2%; Network card and measurement bandwidth DC ~ 1MHz; |
6 in 1 Safety Tester
AC Hipot, Insulation Resistance, Ground Bond, Leakage Current, Power/Start; Safety accuracy: 2%; Classic model, well sold for over 20 years; |
Reviews