One stop shop for next-generation test and measurement devices!
[GTranslate]
Test Equipments Test Equipments
Select category
  • Select category
  • Calibration Verification Boxes
  • Device Equipments
  • Force Measuring Instruments
  • Measuring Devices
  • Our Representatives
    • Ainuo Products
      • Ac Power Supplies
      • Portable Power Supplies
      • Power Analyzers
      • Safety Testing Equipment
    • DTE | Dnipro Energy Technologies
  • Probes and Gauges
  • Test Equipments › Categories
    • Cable Testing Equipment
    • Combustion Testing Equipment
    • Conditioners and Vibration Testers
    • Electrical Appliances Testing Equipment
    • Electrical Safety Test Equipment
    • High Voltage Test Equipment
    • IP Testers and Probes
    • Lighting Test Equipment
    • Mechanical Impact Testing Machines
    • Plug Socket Switch Test Equipment
    • Relay and Breaker Test Equipment
    • Transformer Test Equipment
Test Equipments Test Equipments
Menu
Browse Categories
  • Test Equipments › Categories
    • Cable Testing Equipment
    • Combustion Testing Equipment
    • Lighting Test Equipment
    • Electrical Appliances Testing Equipment
    • Electrical Safety Test Equipment
    • Plug Socket Switch Test Equipment
    • IP Testers and Probes
    • Mechanical Impact Testing Machines
    • Relay and Breaker Test Equipment
    • Conditioners and Vibration Testers
    • Transformer Test Equipment
    • High Voltage Test Equipment
  • Measuring Devices
  • Device Equipments
  • Calibration Verification Boxes
  • Probes and Gauges
  • Force Measuring Instruments
  • Our Representatives
    • Ainuo Products
      • Ac Power Supplies
      • Portable Power Supplies
      • Power Analyzers
      • Safety Testing Equipment
    • DTE | Dnipro Energy Technologies
  • HOME
  • Corporate
    • About Us
    • Our Certificates
    • Human Resources
    • FAQ
  • Our Services
  • News
  • Catalogs
  • Contact
  • EnglishEnglish
    • TürkçeTürkçe
    • EnglishEnglish
Home Our Representatives Ainuo Products Safety Testing Equipment Electrical Safety Comprehensive Tester AN9640BV3(F)
Multitech-Güç-Analizörü
Digital Power Meter | MT9940N
Back to products
ctptanalyzer-multitech
CT PT Analyzer | MTCP-III
aiunuo_akıllı-güvenlik-test-cihazı-3
aiunuo_akıllı-güvenlik-test-cihazı-1
Click to enlarge

Electrical Safety Comprehensive Tester AN9640BV3(F)

From medical devices to appliances, AINUO AN Series all-in-one design includes the test functionality you need to ensure your product is compliant with the most rigorous international electrical safety test standards.

DEVICE INTRODUCTION VIDEO

BARCODE READING FEATURE DESCRIPTION

Get Quote
SKU: AN9640BV3(F) Categories: Safety Testing Equipment, Test Equipments › Categories
Share:
  • Description
  • Reviews (0)
Description
  • The AC Hipot Test allows you to stress your product’s insulation with high voltage to ensure it will limit current flow should a fault occur.
  • Output 100 mA of AC Hipot/Dielectric Withstand test current. Ainuo AN Series meets the 200 mA short circuit requirement for 500 VA Hipot Testers.
  • The DC Hipot Test allows you to stress your product’s insulation and limit leakage current output by running a DC dielectric withstand test.
  • The Ground Bond,Verify the integrity of your product’s protective earth ground conductor to prevent electric shock should a fault occur.
  • The The Ground Continuity,Verify the presence of your product’s protective earth ground conductor to prevent electric shock should a fault occur.
  • The Insulation Resistance,Determine the total resistance of your product’s insulation.
  • The Leakage Current,Ensure your product’s leakage current remains at acceptable levels during 8 different fault conditions.
  • The Functional Run,Verify that your product is working properly before shipment.

 

DESCRIPTION OF PRODUCT

  The new Ainuo AN96 series safety tester has integrated seven functions (seven-in-one: AC withstand voltage, DC withstand voltage,insulation resistance, ground bond resistance, leakage/contact current, operating power, low voltage start-up, providing safety test solutions for household appliances, energy-saving lamps, medical devices, information equipment, electric vehicles, photovoltaic energy, power electronics and other industries, and innovative solutions for various intelligent automated tests.

 

PRODUCT FEATURES

  • Precise: basic Accuracy: 1%; Accuracy of electrical parameters: 0.2%;
  • Fast: Accurate testing within 0.5s, 0.1s fast switching, high-speed communication, high efficiency.
  • Integration: integrate safety performance and electrical performance seven functions in one, one-key start for a station;
  • Intelligent: Built-in 100 groups of test conditions, barcode recognition, automatic matching of test program.
  • Automation: RS232(standard)/RS485/GPIB/LAN ports, barcode scanning interface, frequency conversion power control interface, easy to form an automated test system.

 

AN9640BV(F)  Electrical Safety Comprehensive Analyzer
Features Technical indicator
AC WITHSTAND VOLTAGE TEST
Rated output capacity 500VA(5000V/100mA),short-circuit current more than 200mA
Output voltage range/accuracy 100~5000V,±(2%×setting +5 counts)
Output frequency range/accuracy 50Hz or 60Hz,±0.1%×setting
Alarm current setting Upper limit range/accuracy 0.10~40.00mA,±(2%×setting +5counts)
Lower limit range/accuracy 0.10~40.00mA,±(2%×setting +5counts)
Time setting Range of test time 0.5~999.9s(0 is infinite)
Range of ramp-up time 0.1~999.9s
Range of ramp-down time 0.1~999.9s
Time setting accuracy ±(1%×setting + 1count)
Measurement meter Voltage range/accuracy 0.01~5.00kV,±(1%× reading +1 count)
Frequency range/accuracy 50Hz or 60Hz,±0.1%×reading
Current range/accuracy 0.10~40.00mA,±(1%×setting +5 counts)(
Time range/accuracy 0.1~999.9s,±(1%×reading +1 count)
Output voltage waveform/degree of distortion/ Regulation rate Sine wave,<2%(pure resistance load),

<(1%×setting+5V)(from no-load to full-load)

Initial voltage setting (0%~50%)×Output voltage setting
Current compensation setting 0.000~ 10.00mA,Outomatic
Arc detection 1~9 levels, level-9 corresponds to the  most sensitive, 0 is Off
DC WITHSTAND VOLTAGE TEST
Output voltage Range/accuracy 100~6000Vdc,±(1%×setting+5 counts)
Alarm current setting Upper limit range/accuracy 0~10000μA,±(1%×setting +5 counts)
Lower limit range/accuracy 0~999.9μA,±(1%×setting +5 counts)
Time setting Range of test time 0.5~999.9s(0 is infinite)
Range of ramp-up time 0.4~999.9s
Range of ramp-up time 1.0~999.9s(0 is off)
Accuracy ±(1%×setting +1 count)
Measurement meter Voltage range/accuracy 0.01~6.00kVdc,±(1%×reading +5 count)
Current range/accuracy 0.0~10000µA,±(1%×reading +5 counts)
Time range/accuracy 0.1~999.9s,±(1%×reading +1 count)
Rated output capacity 60VA(6000Vdc/10mA)
Output adjustment level ± (1%×setting +5 V), empty load to full load
Compensating current setting 0 ~200.0μA,automatic, manual
Initial voltage setting (0%~50%)× setting Output voltage
Lower limit current for charging (0~350)μA,automatic, manual
Discharging time ≤200ms
Arc detection 1~9 levels, level-9 corresponds to the  most sensitive, 0 is Off
INSULATION RESISTANCE TEST
Output voltage Range/accuracy 100~2500Vdc,±(1%×setting +5V)
Alarm resistance setting Range of upper/lower limit 1~50000 MΩ

The upper limit includes no upper setting

Accuracy Range:

1 MΩ~50.00GΩ

Resolution: 0.001MΩ /0.01MΩ /0.1MΩ /0.001GΩ /0.01GΩ

Error:

100V~499V:0.100MΩ~2.000GΩ, ± (5%× reading +2 words)

500V~2500V: 0.100MΩ~999.9MΩ, ± (2%× reading +2 words)

1.000GΩ~9.999GΩ: ± (5%× reading +2 words)

10.00GΩ~50.00GΩ: ± (15%× reading +2 words)

Time setting Range of ramp-up time 0.1~999.9s
Range of delay time 0,0.5~999.9s(0 is infinite)
Range of test time 1.0~999.9s,off
Range of ramp-down time 1.0~999.9s,off
Setting accuracy ±(1%×setting +1 count)
Measurement meter Voltage range/accuracy 100~2500Vdc,±(2%×reading +5 counts)
Resistance range/accuracy Range:

1 MΩ~50.00GΩ

Resolution: 0.001MΩ /0.01MΩ /0.1MΩ /0.001GΩ /0.01GΩ

Error:

100V~499V:0.100MΩ~2.000GΩ, ± (5%× reading +2 words)

500V~2500V: 0.100MΩ~999.9MΩ, ± (2%× reading +2 words)

1.000GΩ~9.999GΩ: ± (5%× reading +2 words)

10.00GΩ~50.00GΩ: ± (15%× reading +2 words)

Time range/accuracy 0.1~999.9s,±(1%×reading +1 count)
Lower limit current for charging 0~3.500μA,automatic, manual
GROUNDING RESISTANCE TEST
Rated output Max output is 32A, max testing resistance 600mΩ,open-circuit voltage <12V
Output current setting Range/accuracy 2.0~32.0A±(1%×setting +2 counts)
Output voltage setting Range/accuracy 3.0~10.0V ,±(1%×setting +2 counts)
Output frequency setting Range/accuracy sine,50Hz or 60Hz,±0.1%×setting
Alarm limit setting Range of resistance upper/lower limit Range: (0.1~600) mΩ, (2.0~10.6) A; (0.1~R) mΩ, (10.7~32.0) A. Resolution: 0.1/1 mΩ

Where R= (6400 / current setting ) mΩ

Error Error: ± (1%× setting +2 words)
Compensation resistance setting Range 0~200 mΩ,automatic measurement, compensation on/off
Test time setting Range/accuracy 0.5~999.9s(0=infinite);±(1%×setting +1 count)
Measurement meter Current range/accuracy 2.0~32.0A,±(1%×reading+2 counts)
Voltage range/accuracy 3.0~7.5V ,±(1%×reading +2 counts)
Resistance range/accuracy Range: (10.0~99.9) mΩ. (100~600) mΩ. Resolution: 0.1/1 mΩ.

Error: ± (1%× reading +2 words)

Time range/accuracy Range: 0, (0.5~999.9) s, 0: infinite. Resolution: 0.1s. Accuracy: ± 0. 1%× setting + 2 word)
LEAKAGE CURRENT TEST
Test Mode Single phase load, leakage current at operating temperature (dynamic) and leakage current at non operating temperature (static), L G, N G, AUTO (G L, G N); Require external isolation transformer or inverter power to provide the required test voltage and frequency.
Working power state Polarity: On, Off, Auto; Zero line: On, Off; Earth line: On, Off
Built in human network Polarity switch:
Setting of alarm voltage Range: 20.0V~300.0V AC. Resolution: 0.1V. Error: ± (0.4%× setting +0.1%× ra

nge)

Voltage measurement Range: 0.0V~300.0V, 45Hz~65Hz

Accuracy: 20.0V~300.0V: ± (0.4%× reading +0.1%× range)

Load current Upper limit: 30A
Settings of Touch/Leakage

current upper/lower limit (rms)

Range: 0.0μA~12.00mA. Resolution: 0.1μA /1μA /0.01mA

Error: DC, 15Hz≤f≤100kHz: ± (

1.5 %× setting 10 words)

100kHz f≤1000kHz: ±5%× setting

Touch/leakagecurrent

measurement (rms)

0.0μA~999.9μA: D C, 15Hz≤f≤100kHz: ± ( 1.5 %× reading 10 words)

100kHz f≤1000kHz, 10.0μA 999.9μA: ±5%× reading

1000μA~7999μA: DC, 15Hz≤f≤100kHz: ± ( 1.5 %× reading 10 words)

100kHz f≤1000kHz, 10μA 7999μA: ±5%× reading

8.00mA~12.00mA: DC: ± ( 1.5 %× reading 10 words)

15Hz≤f 1000kHz, 0.01mA~12.00mA: ±5%× reading

LC Compensation Range: 0.000~1.000mA, Auto measurement, On or Off.
Duration Range: 0, (1 ~999.9), 0: infinite. Resolution: 0.1s. Accuracy:± 0. 1%× setting + 2 word), (for testmode AUTO (G L, G N): half of the duration)
DC input impedance 2kΩ ± 1% (GB12113Figure 4)
Input impedance ≤100kHz 5%; >100kHz 10%
Frequency response Accuracy: same as current measurement error
PA TEST (POWER PARAMETER MEASUREMENT)
Alarm Power upper/lower limit alarm;
Settings of power upper/lower

limit

Range: 0.00W~6000W. Resolution: 0.01W /0.1W /1W,

Error: ± (0.1%× setting +0.1%× range)

Active power measurement Range: 0.10W~6.000kW. Resolution: 0.01W /0.01W /0.1W /0.001kW

Accuracy: >PF 0.5: ± (0.1%× reading +0.1%× range)

PF≤0.5: ± (0.4%× reading +0.1%× range)

Voltage measurement Range: 5.00V~300.0V, peak factor: ≤1.6. Resolution: 0.01V /0.1V;

Accuracy: ± (0.1%×reading +0.1%× range), 45Hz≤f≤65Hz

Current measurement Range: 0.00mA~25.00A , peak factor: ≤1.6. Resolution: 0.01mA /0.1mA /0.001A /0.01A

Accuracy: ± (0.1%× reading +0.1%× range), 45Hz≤f≤65Hz

Power factor measurement Range: ± (0.100~1.000). Resolution: 0.001

Accuracy: ±0.01 (voltage/current amplitudes are greater than 10% of the

corresponding ranges)

Frequency measurement Range: 45.00Hz ~65.00Hz. Resolution: 0.01Hz. Accuracy: ± (0.1%× reading )
Duration Range: 0, (0.5~999.9) s, 0: infinite. Resolution: 0.1s. Accuracy:± 0. 1%× setting + 2 word)
ST TEST (LOW VOLTAGE START TEST)
Settings of current upper/lower

limit

Range: (0.00~25 .00) A. Resolution: 0.01A. Error: ± (0.1%× setting +0.1%×
Voltage measurement Range: 5.00V~300.0V,peak factor: ≤1.6. Resolution: 0.01V /0.1V;

Accuracy: ± (0.1%× reading +0.1%× range), 45Hz≤f≤65Hz

Current measurement Range: (0.02~25 .00) A, peak factor: ≤1.6. Resolution: 0.01A

Accuracy: ± (0.1%× reading +0.1%× range), 45Hz≤f≤65Hz

Duration Range: 0,(0.5~999.9) s, 0: infinite. Resolution: 0.1s. ± 0. 1%× setting + 2 word)
FUNCTIONAL INTERFACE
Remote controller interface Standard, optional foot switch (start up)
Alarm lamp connector Standard, optional three-color alarm lamp ( test, pass, alarm)
Communication port Standard, network port, RS232,RS485, GPIB

one of four options, default RS232

Barcode interface Standard, RS232 interface, barcode automatic recognition and programming match
U disk storage connector Standard, support standard U disk connector, test data automatic storage
Switching value interface Standard, can output the switching value of startup, stop, test, pass and alarm
Printer connector Standard, support needle printer an d micro-printer
Rear panel test output interface Standard, rear panel output interface of high-voltage and grounding tests
GENERAL SPECIFICATIONS
Verification and calibration environment 23℃±5℃,(45~75)%RH,little dust
Operating environment 0 ºC ~40ºC,,(20~90)%RH,little dust
Storage environment -10℃~50℃,(5~95)%RH,24h
Input Power AC 220V±10%, 50Hz±5%, 10A
Power consumption of system Max 550W
Weight About 45kg
Dimension (mm, without external package) 483(W)x178(D)x 550(H)

 

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Electrical Safety Comprehensive Tester AN9640BV3(F)”

Your email address will not be published. Required fields are marked *

Related products

MTS-TLNoL-100 Trafo boşta yükte kayıp ölçme test cihazı

Load No-Load Tester | MTS-TLNoL-100

It measures transformer load current, load loss, short circuit voltage, short circuit (load) losses. Harmonic test can be analyzed up to 31 harmonics. All relevant test results are automatically corrected. The instrument can automatically: waveform correction, temperature correction, non-rated voltage correction, calibration and other non-rated current correction for more accurate test results. You can store 500 sets of experimental results.
Read more
Quick view
Multitech-Güç-Analizörü

Digital Power Meter | MT9940N

MT9940N Series Intelligent Electric Quantity Measuring Instrument(Digital Power Meter), Can Measure The Voltage,Current,Power,Power Factor,Frequency,Electric Energy And Other Parameters ,Rich In Content,Has A Wide Measuring Range, The Preset Alarm,Latches And Communications Function. The MT9940N Series Has All The Measurement And Display Function,Increases The Maintain Data Function,As Well As The Display Function Of Frequency And Power (Energy) These Two Parameters On The Basis Of The Original RK9800. MT9901N Increase The Limit Alarm Function Of Current And Power Based On The MT9800N. MT9940N And RK9980N Expand The Range Of Current (Maximum For 40A And 80A Respectively)Based On RK9901N,It Can Measure The Current And The Products With More Power.
Read more
Quick view

Dry Air Sterilization (Etüv) | MTE-Series

MTE Series dry air sterilizers are designed for use in research and industrial laboratories, sterilization, drying, heating, heat treatment and long-term stability testing applications. They provide very good temperature control for homogeneous heat distribution and stable temperatures. Thanks to the fan circulation system controlled by a reliable and sensitive PID microprocessor control system, precise and constant temperatures are achieved. It has an easy to use digital control panel.
Read more
Quick view

Electromagnetic Precision Flow Meter | LT-LDE-DN15

LT-LDE-DN15 Electromagnetic Precision Flowmeter; For IP tests, a safe measurement value is taken by precise measurement of the flow rate.
Read more
Quick view

Etüv | MTN-55

MTN-55, is an easy-to-use control panel with separate displays for temperature and timer. The inner cell is made of stainless steel. Thanks to the sealed glass door under the metal door, samples can be observed inside the cell without causing a temperature drop.
Read more
Quick view

Transformer DC Resistance Tester 40 Amper | MTS-TWR-40

The DC Resistance transformer to meet fast measurement requirement, we developed MTS-TWR-40 DC Resistance Tester. The instrument is a new powerful technology, small size, light weight, high output current and other characteristics.
Read more
Quick view

Grounding Resistance Tester | MT78XR

The mt78xr grounding resistance tester ıs used to measure the ınternal grounding resistance of electrical equipment, which ıt reflect the (contact) resistance between the total ground terminals of the electrical equipment. It ıs suitable for measuring the resistance value between the outer casing and the ground wire of various kinds of motors, electric appliances, ınstruments and meters, domestic appliance and so on. This series of tester according to the following standards:standard for household electrical appliances (IEC6035, GB4706.1-2001,  GB4706.1-1998), standard for lamp(IEC60598-1-1999,  GB7000.1-2000), standard for ınformation (GB8898-2001, GB12113. GB4943-2001,  IEC60065,IEC60950) and so on.
Read more
Quick view

Tracking Tester | MTC-LTE100

MTC-LTE100 has been produced in accordance with IEC60695 and IEC 60112 standards to determine the CTI (Comparative Tracking Index) and PTI (Proof Tracking Index) values of the pollution degree of the material originating from the external environment.
Read more
Quick view

Our company, which provides service in the production, import and export of Test Devices, provides production, supply, maintenance and repair services in accordance with international standards by prioritizing customer satisfaction with its expert staff.

Phone
+90 530 015 50 13
+90 532 678 20 32
+90 312 385 26 36
Mail
satis@multitechteknoloji.com
info@multitechteknoloji.com
Address
Turgut Ozal Mahallesi, 1467/1 Caddesi, No:42 J Astor Plaza 06374 Yenimahalle - ANKARA - TURKEY
Working Hours
Week days 8:30 - 18:00
Friday 8:30 - 16:00
Sunday Closed
Test Equipments 2019 | Privacy Policy | Cookie Policy
  • Menu
  • Categories
  • Test Equipments › Categories
    • Cable Testing Equipment
    • Combustion Testing Equipment
    • Lighting Test Equipment
    • Electrical Appliances Testing Equipment
    • Electrical Safety Test Equipment
    • Plug Socket Switch Test Equipment
    • IP Testers and Probes
    • Mechanical Impact Testing Machines
    • Relay and Breaker Test Equipment
    • Conditioners and Vibration Testers
    • Transformer Test Equipment
    • High Voltage Test Equipment
  • Measuring Devices
  • Device Equipments
  • Calibration Verification Boxes
  • Probes and Gauges
  • Force Measuring Instruments
  • Our Representatives
    • Ainuo Products
      • Ac Power Supplies
      • Portable Power Supplies
      • Power Analyzers
      • Safety Testing Equipment
    • DTE | Dnipro Energy Technologies
  • HOME
  • Corporate
    • About Us
    • Our Certificates
    • Human Resources
    • FAQ
  • Our Services
  • News
  • Catalogs
  • Contact
  • EnglishEnglish
    • TürkçeTürkçe
    • EnglishEnglish
aiunuo_akıllı-güvenlik-test-cihazı-3

Electrical Safety Comprehensive Tester AN9640BV3(F)