FEATURES:
By selecting the voltage rise and current rise value and rise times, it can perform the tests of high voltage, insulation resistance and grounding continuity in stepwise or ascending direction.
Suitable for type tests and routine tests.
– It can perform AC / DC high voltage, insulation resistance and ground resistance tests.
– Standard, preventive security system (OK light, high voltage indicator, high voltage column indicator)
– Fast voltage rise time (Within 100ms)
– Automatic measurement stability control system
– It can test the loads with resistive, capacitive and inductive properties with different characteristics.
– Discharge in 2 seconds
– The voltage rise time, test time and test interval time can be adjusted.
– Arc detection and arc detection level can be adjusted.
– 20 memory groups, 8 test levels
– Both cycle test and single step test can be performed.
– Records the start and reset times with the statistics function.
– 50Hz, 60 Hz opsionel frequency.
-Standard PLC interface, optional remote test probe and U disk storage.
Technical Parameters:
HIGH VOLTAGE TEST | ||||||
Model | Out put volt age (kV) | Test Cur rent (mA) | Accu racy | Test Time | Freq uency | |
MT- 9933 D/NE | 0.20- 5.000 / 6.000 | 0-20 / 10 ( AC / DC) | ± ( 2 % + 5 V ) | (0.0- 999.9 )s | 50/ 60 HZ | |
INSULATION RESISTANCE TEST | ||||||
Model | Out put volt age (kV) | Accu racy | Test Time | Resis tance Range | ||
MT- 9933 D/NE | 0.50 – 1.00 | ±( 2 % + 5 V ) | (0.0 – 999 .9 ) s | 1MΩ – 5.0 GΩ | ||
GROUNDING CONTINUITY TEST | ||||||
Model | Trans former (A) | Accuracy | Test Time | Resis tance Range | ||
MT- 9933 NE | 5.0- 32.0 | ±(2%+2mΩ) | (0.0- 999.9) s | (1~510) mΩ | ||
MT- 9933 DE | 5.0- 25.0 | ±(2%+2mΩ) | (0.0- 999.9) s | (1 ~510) mΩ |