High Voltage Test System for Solid Dielectrics Testing

High Voltage Test System for Solid Dielectrics Testing

  1. Testing the high-voltage cables and the cables sheaths with 6,10,15,20 kW operating voltage and all types insulation such as XLPE and PILC.
  2. Testing insulators and other electric equipment by high voltage power frequency AC.
  3. Testing high-voltage switches’ vacuum chambers.
  4. Laboratory and research works.

Features: The test system contains a few units, which are easy to carry and use. For example, only one high-voltage unit without the switching unit is needed for testing the transformer substations’ isolators.
The system includes a convenient and maneuverable transport cart.

Order Now
Description

High Voltage Test System for Solid Dielectrics Testing;

  1. Testing the high-voltage cables and the cables sheaths with 6,10,15,20 kW operating voltage and all types insulation such as XLPE and PILC.
  2. Testing insulators and other electric equipment by high voltage power frequency AC.
  3. Testing high-voltage switches’ vacuum chambers.
  4. Laboratory and research works.

Features: The test system contains a few units, which are easy to carry and use. For example, only one high-voltage unit without the switching unit is needed for testing the transformer substations’ isolators.
The system includes a convenient and maneuverable transport cart.

Technical Specifications

Parameter name Value
Power supply AC voltage 220 V ± 10%(50Hz)
Maximum supply current, at most 5 A
Environment temperature -10…+45 °C
Storage temperature -20… +45 °C
Relative air humidity at + 25 ° C,%, at most 80
Atmospheric pressure, mm Hg. 630 – 800
The total weight with the transport cart, at most 115 kg
Long operation mode, at least 120 min.
Average service time 10 years

Output Voltage

Parameter name Value
Maximum voltage in ultra-low frequency (ULF) generator mode, cosine-rectangular (squarewave) waveform 40 kV
Three fixed ULF generator’s frequencies 0,1; 0,05; 0,02 Hz.
Maximum voltage in DC rectified voltage generator mode +⁄- 40 kV
Maximum voltage in AC sinusoidal voltage generator mode (frequency 50 Hz) 50 kV
Maximum load capacity in the ULF generator mode with frequency 0,1 Hz – 0,3 (µF)0,05 Hz – 0,6 (µF)

0,02 Hz – 1,5 (µF)

Output voltage measuring accuracy 3 %
Output voltage measurement resolution 100 V

Output Current

Parameter name Value
Maximum current of the test system in all modes 14,5 mA
Two output current measuring range 1 mA ⁄ 20 mA
Output current measurement resolution 3 %

Built-in timer for three fixed time interval (1 min., 5 min., 30 min.) with real-time clock function. Upon reaching the time setting, it automatically turns off the test mode, with sound and light indication.

High Voltage Test System for Solid Dielectrics Testing Package Contents

Name Quantity Notes
1 Control unit CU 1
2 High voltage unit HVD-50 1
3 Switching unit SU-40 1
4 Transport cart 1
5 Power cable 1 1,75 m
6 High voltage wire 1 3,5 m
7 Ground wire 3 3,5 m
8 Interconnect wires set 4 suite
9 Fuse-link 5 × 20 2 250 V, 1 A
10 Fuse-link 6 × 30 2 250 V, 10 A
11 Operation Manual 1
12 Calibration certificate 1