Ground Bond Tester Ainuo
Ground Bond Tester Ainuo
* Latest international standard: Comply with CCC,IEC,EN,VDE,BS,UL,JIB standard requirements.
* Result can be shown as resistance or voltage to satisfy different industrial standard requirements
* Measurement current 5-30A, output frequency 50/60Hz
* Leakage current upper setting, intelligent judgment
* VFD display, simple operation
* Remote, RS232/485 interface
Ground Bond Tester Ainuo; measurement current 5-30A, output frequency 50/60Hz
* Latest international standard: Comply with CCC,IEC,EN,VDE,BS,UL,JIB standard requirements.
* Result can be shown as resistance or voltage to satisfy different industrial standard requirements
* Measurement current 5-30A, output frequency 50/60Hz
* Leakage current upper setting, intelligent judgment
* VFD display, simple operation
* Remote, RS232/485 interface
Ground Bond Tester Ainuo Technical Parameters
Model | AN9613X(F)E | |
AC Output | Current range/ Resolution/ Accuracy | 5.0~30.0A ,0.1A,±(3% of setting+5 counts) |
Voltage | <12V | |
Frequency | 50Hz/60Hz ±100ppM | |
Parameter Setting | Resistance set range/Resolution | 1~600mΩ(below 10A), 1~300 mΩ(10-25A) 1~200 mΩ (above 25A) 1 mΩ/step |
Voltage set range/Resolution | 0.01~6.00V(below 10A),0.01~7.5V(10~25A) 0.01~600V(above 25A) 0.01V/step | |
Time set range/Resolution | 1.0~999.9s(LLL=continuous), 0.1s/step | |
Measuring Function | Measurement voltage | 0.01~3.00V, ±(3% of reading+5 counts) |
Resistance range/Accuracy | 1~600 mΩ, ±(3% of reading+5 counts) 300~7.50V, ±(3% of reading) | |
Max rated load | 180VA | |
Current fluctuation | ≤1% | |
Interface function | RS232(RS485 optional), Remote control | |
Dimension (W×H×D) | 320×110×400mm |