Programmable High Voltage – Insulation Tester is designed to perform the High Voltage Test and Insulation Resistance Measurement Test foreseen in electrical safety standards.
Programmable High Voltage – Insulation Tester Technical Parameters:
FUNCTION | PARAMETRES |
AC High Voltage Test | 5KV AC |
AC Output Frequency | 50Hz or 60Hz, adjustable |
AC Output Waveform | Sine wave,
1.3< crest factor <1.5 |
Leakage Current for AC High voltage Test | Range: 0.01-20.00mA
Resolution: 0.01 A Accuracy: ± ( 2 % set + 2 digits) |
DC High Voltage Test | 6KV DC |
Leakage Current for DC High voltage Test | Range: 0.01-10.00mA
Resolution: 0.01 A Accuracy: ± (2 % set + 2 digits) |
AC-DC Voltage Adjustment | Range: 0-5000VAC
Range: 0-6000V DC Resolution: 1V Accuracy: ± (2 % +5V) |
Voltage Stability | 1 % set + 5V |
Rise Time | Resolution: 0.1 S |
Accuracy: ± (0.1 % set +0.05 s ) | |
Test Time | Range: 0.5-999.9 s |
Resolution: 0.1 s | |
Accuracy: ± (0.1% set +0.05 s) | |
ARK recognition | ARK recognition on: 1-9 adjustable, ARK recognition off: 0 |
Insulation Resistance Test | 1000V DC |
Insulation Test Voltage Adjustment | Range: 500-1000V DC
Resolution: 1V Accuracy: ± ( 2 % set+5 V) |
Insulation Test Voltage Display | Resolution: 10 V |
Insulation Test Resistance Display | Range: 1.000-2000 MΩ
Accuracy: ± (5 % reading +3 digits) (1-1000 M Q) Accuracy: ±(10% reading +3 digits) (1000-2000 M Ω) |
Insulation Resistance Upper Limit Setting | 0- 2000 M Ω, 0: No limit |
Insulation Resistance Lower Limit Setting | 1.0-999.9 M Ω |
Test Delay Time | Range: 0.8-999.9; 0: Continuously Test
Accuracy: ± (0.1% reading +0.05 s) Resolution: 0.1 s |
Dimensions (Height x Width x Height) | 400x320x130mm |
Weight | 10 Kg |