MT-9922BX;
- With safety anti-electric wall function, it can automatically detect whether the input power is correct.
- High-voltage variable frequency, range 40.0~400.0Hz, resolution 0.1Hz. Can be used as a variable high voltage source
- After the DC withstand voltage and insulation resistance test is completed, the tester can quickly discharge in 0.2 seconds to protect the operator’s safety.
- With the current lower limit alarm function, it can prevent the test line from being opened during the test. The misjudgement caused by measuring components
- Has a keyboard lock function to prevent the operator from modifying the test parameters to ensure that the measured body is tested according to the set parameters.
- The linear power amplifier drives the output sine wave voltage (current), and the crest factor is in the range of 1.3 to 1.5. Inside
- Use 240×64 drawing LCD display, user-friendly interface design
- English display interface, can meet the different needs of different users
- Pre-set save test parameters: 30 files can be set, each file can be Set 99 test steps
- Optional RS232, RS485, USB interface, standard PLC interface
Technical Parameters
HIGH VOLTAGE TEST
Mod | Out put volt age (kV) | Test Current (mA) | Accu racy | Test Time | Freq uency | Arc Detec tion (mA) |
MT- 9922 BXE | 0.050 ~ 5.000 / 6.000 | 5.0mA ~ 20.00 (AC) 0.050 µA ~ 10.00 (DC) | ± ( 2 % + 2 ) | (0.0 ~ 999 .9)s | 40.0 ~ 400.0 Hz | 0 ~ 20.00 / 10.00 |
MT- 9922 CXE | 0.050 ~ 5.000 | 5.0µA ~ 20.00 (AC) | ± ( 2 % + 2 ) | (0.0 ~ 999 .9)s | 40.0 ~ 400.0 Hz | 0 ~ 20.00 (AC) |
MT- 9922 DXE | 0.050 ~ 5.000 / 6.000 | 5.0µA ~ 50.00 (AC) 0.050 µA ~ 20.00 (DC) | ± ( 2 % + 2 ) | (0.0 ~ 999 .9)s | 40.0 ~ 400.0 Hz | 0 ~ 50.00 / 20.00 |
MT- 9922 EXE | 0.050 ~ 5.000 / 6.000 | 5.0µA ~ 100.00 (AC) 0.050 µA ~ 50.00 (DC) | ± ( 2 % + 2 ) | (0.0 ~ 999 .9)s | 40.0 ~ 400.0 Hz | 0 ~ 100.00 / 50.00 |
MT- 9922 FXE | 0.050 ~ 5.000 / 6.000 | 5.0µA ~ 100.00 (AC) 0.050 µA ~ 50.00 (DC) | ± ( 2 % + 2 ) | (0.0 ~ 999 .9)s | 40.0 ~ 400.0 Hz | 0 ~ 100.00 / 50.00 |
INSULATION RESISTANCE TEST
Model | Out put volt age (kV) | Resis tance Range | Accuracy | Test Time |
MT- 9922 BXE | (0.050 ~ 1.000) (DC) ± (2%+5V ) | 1MΩ~ 9.999 GΩ | ± (5%+2) | (0.0 ~ 999.9 )s |
MT- 9922 CXE | (0.050 ~ 1.000) (DC) ± (2%+5V ) | 1MΩ~ 9.999 GΩ | ± (5%+2) | (0.0 ~ 999.9 )s |
MT- 9922 DXE | (0.050 ~ 1.000) (DC) ± (2%+5V ) | 1MΩ~ 9.999 GΩ | ± (5%+2) | (0.0 ~ 999.9 )s |
MT- 9922 EXE | (0.050 ~ 1.000) (DC) ± (2%+5V ) | 1MΩ~ 9.999 GΩ | ± (5%+2) | (0.0 ~ 999.9 )s |
MT- 9922 FXE | (0.050 ~ 1.000) (DC) ± (2%+5V ) | 1 MΩ~ 50.00 GΩ | ± (5%+2) | (0.0 ~ 999.9 )s |
GENERAL INFORMATION
What is High Voltage Test?
The purpose of the high voltage test is to check the insulation by measuring the dielectric strength over high voltage.
Why is High Voltage Test Done?
High voltage test; It tests the resistance of the insulation material that prevents all accessible metal parts under normal conditions on the machine or device from contacting the user.
Insulation Resistance Measurements,
Insulation Testers are test devices that measure insulation resistance. In a normal working environment, insulation must be provided between the parts that have voltage and the parts that are not. If insulation is not provided, there will be electricity in places where electrical energy should not be available and it will pose a danger to life safety. In addition, insulation should be provided between the parts inside the devices. This is very important in the operation of the devices.
- One of its most important advantages is that it can be used in many areas.
- With many different step settings, you can choose the appropriate level very easily.
- It allows the measurement of very high insulation resistance values.
- There are automatic discharge systems after each test.
- The data can be analyzed with special software prepared for the computer.
- It provides the opportunity to follow the measurements live.
Reviews