Cylindrical Rod With Hemispherical End For
Cylindrical Rod With Hemispherical End For meets the standard of IEC 60335-2-14 Clause 20.103. This rod is designed to test accidental operation of the switches used in the hand-held blenders in order to prevent accidental operation, in which the actuating member is positioned in a recess or otherwise guarded.
Cylindrical Rod With Hemispherical End For; is designed to test the accidental operation of switches in hand-held blenders in accordance with TS EN 60335-2-14 Article 20.103, the actuating element of which is positioned in a recess or otherwise protected to prevent accidental operation.
Test method:
A cylindrical rod with a hemispherical end is applied to the actuating element of the switch with a force not exceeding 5 N.
The device must not operate.
Technical Parameters
- Rod diameter: Φ 40 mm
- Rod material: Stainless steel
- Handle: Nylon
TS EN 60335-2-14 Hemispherical Cylindrical Rod
It is a test tool used to ensure the safety of electrical kitchen machines. This standard defines specific safety requirements specifically for kitchen machines and specifies the test procedures necessary to evaluate the performance of the devices.
Scope of the Standard
- Home and Similar Use: TS EN 60335-2-14 focuses on the safety of electrical kitchen machines for household and similar use with a rated voltage of not more than 250 V.
- Kitchen Machines: This standard covers food processors, mixers, choppers and other similar devices. In the design of such devices, measures should be taken to minimise various hazards to ensure the safety of users.
Cylindrical Rod with Hemispherical End
Cylindrical rod with hemispherical tip is used as part of the tests contained in this standard. This probe is designed to measure the surface temperatures of devices and to assess the accessibility of moving parts.
Areas of Use
- Safety Tests: The hemispherical cylindrical rod is used in tests to ensure user safety in the design of kitchen machines. These tests are important to check that the surface temperatures of the appliance are at safe levels.
- Quality Control: Manufacturers carry out such tests to ensure that their products comply with the TS EN 60335-2-14 standard. Thus, while increasing the safety of end users, product quality is also improved.
TS EN 60335-2-14 Hemispherical End Cylindrical Rod plays a critical role in ensuring the safety of electric kitchen machines. Thanks to this standard and related test tools, manufacturers can increase the reliability of their products and ensure that users have a safe experience.