Foam Horizontal Burning Tester is designed to perform horizontal combustion tests for the relative combustion characteristics of small plastic foams with a density not exceeding 250 kg / m³ according to ISO 845 and UL94 standard. ul94 standard flammability test
Features:
This tester uses the integral intake ignition system. The combustion time delays 0.1s thus to make sure the sufficient time of gas burning.
This device has a matte black background, a multifunction flame meter, a stainless steel enclosure, a large observation window, a high precision digital display and a beautiful appearance.
Foam Horizontal Burning Tester Technical Parameters
Parameter/Model | MLT-HVF5E |
Power Supply | 220 V 50 Hz |
Control operation mode | Electrical control, button operation |
Blast burner standard | ISO10093:1998,inner diameter Φ9.5±0.3mm,effective length: 100 ±10mm, with wing section lamp top:48±1×1.3 ±0.05mm |
Gas pressure | 0.1MPa |
Gas flow and gas category | 965±30ml/min, for the methane gas purity of 98% , it can also use the mixed gas or propane gas, flow meter adjustment |
Standards | UL94, ISO 845, ISO 9772 |
Combustion / self extinguishing time | 0-9999×0.1s |
Distance between the wing top of the blast burner to the test sample | 13±1mm |
Flame height | 38±2mm, blue flame |
Support net | 215×75×13mm, grid : Φ0.8 made of stainless steel wire with length of the side of 6.4mm |
Lighting | Equip with lighting in the test chamber, with control |
Test chamber and dimension | >0.5 cube,black matte background,with exhaust fan, dimension: 1100x550x 1200mm, 130kg |
Reviews