AC Resonance Test System | MTS-180
AC Resonance Test System | MTS-180; It is used for factory testing of medium and high voltage cables, high voltage capacitors, generators and motors.
SKU: MTS-180E Category: High Voltage Test Equipment Tags: ac resonance test system, resonance test system
Description
AC RESONANCE TEST SYSTEM | MTS-180
It is used for factory testing of medium and high voltage cables, high voltage capacitors, generators and motors.
- The 35kV/300mm2 cable is 800m, the capacitance is ≤15μF, the test frequency is 30-300Hz, and the test voltage is 52kV.
- 10kV/300mm2 cable 2000m, electric capacity ≤74μF, test frequency 30-300Hz, test voltage 22kV.
- 35kV switch, insulator and busbar AC withstand voltage test, the test frequency is 30-300Hz, and the test voltage does not exceed 100kV.
- 10k motor AC withstand voltage test, the test frequency is 45-65Hz, and the test voltage does not exceed 15kV.
- AC withstand voltage test for transformers with 35kV less than 50000KVA, capacitance ≤02μF, test frequency 30-300Hz, and test voltage 85kV
TECHNICAL PARAMETERS
Rated output voltage | Rated output voltage: 27kV / 54kV / 108kV |
Resonant voltage waveform | sine wave, waveform distortion rate ≤0.5% |
Maximum tested product current | 4A, 2A, 1A |
Maximum test capacity | 108kVA |
Output frequency | 30~300Hz |
Working time | Continuous working time is 60min under full power output |
Quality factor | ≥30 |
Input working power | Single phase 220V±10%, 50Hz |
Ambient temperature | -15℃~+40℃ |
Relative humidity | <90RH%, no condensation |
Altitude | <5000m |
Noise | ≤60dB |
APPLIED STANDARDS
IEC 60076-1 | Power transformers |
IEC 60060-1: 2010 | High-voltage test techniques–Part 1: General definitions and test requirements |
IEC 60060-2: 2010 | High-voltage test techniques–Part 2: Measuring systems |
IEC 60529 | Degrees of protection provided by enclosure (IP Code) |
IEC 62271-301 | Dimensional standardization of high-voltage terminals |
IEC 60076-3 | Power transformers – Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC-60289 | Reactor |
IEC 60358-1 | Coupling capacitors and capacitor dividers |
IEC1000 | EMC |
IEC61010-1 | Safety requirements for electronic measuring apparatus |
Reviews (0)
Be the first to review “AC Resonance Test System | MTS-180”
Related products
High Voltage | Insulation Resistance Tester
Hipot | Insulation Tester
Operation Box
Programmable High Voltage – Insulation Resistance Tester
Programmable High Voltage - Insulation Resistance Tester MT-9922BXE is the first precision variable frequency withstand voltage and insulation resistance tester in the safety industry. The output AC voltage has a frequency range of 40.0Hz~400.0Hz and a resolution of 0.1Hz. The output voltage adopts hardware feedback, high-speed MCU control technology, and the output voltage regulation rate is within 1%, which can be used not only as a withstand voltage tester, but also as a variable-voltage high-voltage source. The three test modes of AC withstand voltage, DC withstand voltage and insulation resistance can be used in any combination. It is a high-performance instrument used for long-term production line for voltage and insulation resistance testing.
Programmable High Voltage Insulation Tester | MT-5120
Programmable Insulation Resistance Tester
Programmable Insulation Resistance Tester; they can quickly and accurately measure the insulation resistance of the electronic components, white goods, insulation materials, instruments and meters, illumination electrical appliance, motor-driven and electro thermal implements. Suitable for type and routine testing.
Tangent Delta Tester | MTS-CTD12
Tangent Delta Tester is applied to measure the dielectric loss and capacitor value of insulation materials in high voltage power equipment. The non-power frequency voltage source is integrated in the tester to avoid power frequency interference. That make the tester has a good performance in measurement precision.
Reviews